40A48 AC current / voltage configurable indicator-alarm unit

Available Configuration:

N° digits
4
Option
None
Output 1, Output 2
Relay, Relay
Relay, Logic
Output 3 (alternative to digital input / retransmission output)
None
Relay
Digital input / Retransmission output (alternative to output 3)
None
Digital input
Analog output 4….20mA on max 150Ohm
Power supply
20….27Vac/dc
100….240Vac

40A48 AC current / voltage configurable indicator-alarm unit Specifications:

Microprocessor based indicator in both 48x48 (1/16 DIN) and 96x48 (1/8 DIN) formats manifactured with SMT. T
he instruments have a lexan membrane faceplate (guaranteed to IP65) which has 3 keys, a 3 digit display for the 48x48 format and a 3 / 4 digit display for the 96x48 format, and 3 indicating LED's for the output statuses.
The input signal section provides for the visualisation of the sinusoidal effective value corresponding to following signals:

  • AC voltage: 0 to 2, 0 to 20, 0 to 200 and 0 to 500Vac
  • AC current: 0 to 20, 0 to 50, 0 to 200mAac 0 to 1, 0 to 5Aac
The selection is made using the faceplate keys and correct input terminals.
No external shunt or adapter is required.
A digital input (24Vdc/4mA) is available for resetting, hold, flash, peak handling or releasing latch.
The instruments have a maximum of 3 outputs that can be mechanical relays (5A/250V) or logic outputs (0 to 11Vdc).
One output of 4 to 20mA (max. 150W) is available for retransmitting the measured input signal.
The retransmission output, the digital input and the third output are alternatives in the 48x48 format, all these options are available contemporaneously in the 96x48 format.
Finally, a triac can be fitted (as an alternative to the other two relay outputs) to drive resistive loads up to a maximum of 2,5A at 220V.
The programming of the instrument is made easy by grouping the parameters in function blocks (CFG for the alarm hysteresis, Inp for the inputs, Out for the outputs...) and by a simplified data entry menu.
The configuration can be simplified even further using the PC programming kit made up of a connection cable and a menu guide program that runs under Windows (see data sheet cod. 80021).
A configurable personal software protection code (password protection) can be used to restrict the levels of editing and displaying the configuration parameters.
  • AC voltage, AC current direct input on instrument terminals
  • Protected code configurable from keypad
  • 4 to 20mA retransmitted output
  • Up to 3 relay outputs
  • Configurable by serial link
  • Labels to customize measured physical unit
 